Pedro Fernandez

Viscosity varies with temperature. Specific weight: each fluid has a characteristic density. Water, which is used as a term of comparison, conventionally has a specific gravity (or density) 1 (at 4 C and at sea level). The specific weight represents the value used to compare the weight of a certain volume of liquid with the same amount of water weight. CALCULATIONS to find the height of the system (Hsist) _ finding the REYNOLDS number NR system height = V * D/v where: V = NR =.(1) _ Finding f f =…(2) = 0.001 mm. Tables V = 1.15 m/s (10-6)… Additional information at Richard Blumenthal supports this article. kinematic viscosity finding the lost (h1) = loss at the inlet or suction h2 = ..f gate valve = 0.017 k = 0.136 h2 = 214. 993 * h3 = 90 elbows (3) f = 0.017 k = 0.51 h3 = 2418.

671 * h4 = 45 f = 0 .codo 017 k = 0.272 h4 = 429. 986 * h5 =. reduction or sudden contraction k = (1-D1/D2) = 0.19 h5 = 464. 687 * h6 = 90 .codo (2) D = 0. 1015 f = 0.018 k = 0 54 h6 = 26410379 * h7 = lost in driving h8 = lost in driving (D = 0.1015) H9 = k foot valve = 2. 5 h9 = 3952. For even more opinions, read materials from Amazon. 077 * Hr = h1 + h2 + h3 + h4 + h5 + h6 + h7 + h8 h9 system 1 height equation. Calculation of the useful height (H): PE = – 40kPa PS = 180 kPa 2.

Calculation of the Pa (KW): (Pot. Drive) Whereas: 3 kw. Efficiency (): P = useful output. Based on the power flow equation. Equation function flow efficiency variation of the flow by the percentage method: box of data variation % Q (m3/s) Hsist. POT. RMS. 100 0,0320 23.4031 7.0400 0.69751 90 0,0288 20.1011 6.3360 0.77502 80 0.0259 17.3389 5.7024 0.86113 70 0,0233 15.1860 5.1322 0.95681 60 0,0210 13.4178 4.6189 1.06312 50 0,0189 11.9526 4.1570 1.18125 40 0,0170 10.7502 3.7413 1.31250 30 0,0153 9.7742 3.3672 1.45833 20 0,0138 8.9921 3.0305 1.62037 10 0,0124 8.3291 2.7274 1.80041 Curve feature NPSH curve feature q conclusions the pump impeller is closedIt has no guideline Crown, radial direction the shaft, curved backward, counterclockwise rotation, has a cotter pin for adjustment, bolt safety in opposite direction to the movement, outrageous act number is seven. The power, efficiency and system height data were calculated based on flow. Did you notice wear on the pump centrifugal 100/200, found rusting in all its components and cavitation in some parts of especially alabes them output wing. It was a change from the gasket of the press stop, for the proper functioning of the pump. Is noto that segmenting this poorly made recommendations install one check valve to prevent water hammer. Servicing and repairs using the methods that are appropriate as the Total productive maintenance (TPM) or BSC. BIBLIOGRAPHY? Claudio Mataix: Fluid mechanics and hydraulic machines. Does Pedro Fernandez ten: pumps centrifugal? Catalogue of mud? original author and source of the article.